| MECHANICAL
Standard Crystal Vision module 266mm x 100mm
Weight: 200g
Power consumption: 8.75 Watts
AUDIO INPUTS
Two 24 bit stereo pairs
AES3 110 ohm (balanced) D-Type, or AES3-id (unbalanced) 75 ohm BNC.
Set by on-board jumper links to 75 ohm, 110 ohm or high impedance for multiple units on a single feed
Works with any sampling rates between 30kHz and 50kHz, usually 32, 44.1 and 48kHz. Clock regeneration for 48kHz
AUDIO OUTPUTS
Maximum of two analogue stereo outputs per channel, using RM03, RM11, RM12 and 'easywire' RM35 frame rear modules
Low impedance balanced (66 ohm) output
Can convert to single channel operation if extra outputs from single input required
Level Range: 0dBFS = +28dBu max; 0dBFS = +12dBu min
Factory set default: 0dBFS = +18dBu and +24dBu by on-board link
Signal to noise: Weighted better than -98dB
Total Harmonic Distortion (THD): <.0025% at +18dBu/+24dBu (48kHz crystal mode)
Interchannel crosstalk: <-110dB
Frequency response: +/- 0.1dB 20Hz to 20kHz
DELAY THROUGH BOARD
100ns
GPI INPUT LEVELS
Connect to ground active
Inactive high impedance or 3 to 48 volts
Input current 50uA
GPI OUTPUT LEVELS
CMOS levels
Max current 20mA
GPI INPUTS
Select 48kHz crystal or auto frequency on AES input 1
Select 48kHz crystal or auto frequency on AES input 2
Swap channels 1 and 2
Single stereo (all outputs from AES input 1)
GPI OUTPUTS
AES errors (one put channel)
Error can be set to include sustained silence. Set period of silence before indication from 1.5 to 120 seconds in eight second increments
LED INDICATION OF:
Power supplies on board
AES input present
AES silent
Sample rate
Remote control
LOCAL CONTROL
Options and silence indication delay set by switches at board edge
REMOTE CONTROL
RS422/485
19200 baud, 8 bits, 1 stop no parity
Control from frame active panel and remote panel
Statesman allows control from any PC on a network
SNMP monitoring and control available as a frame option
|