MECHANICAL
Standard Crystal Vision module 266mm x 100mm
Weight: 155g
Power consumption: 11 Watts

VIDEO INPUTS
Two 3Gb/s, HD or SD inputs
270Mb/s or 1.5Gb/s or 3Gb/s serial compliant to EBU 3267-E, SMPTE 259M, SMPTE 292M and SMPTE 424M
The video formats supported are 625, 525, 720p50, 720p59.94, 720p60, 1080i50, 1080i59.94, 1080i60, 1080p50, 1080p59.94  and 1080p60
3Gb/s cable equalisation up to 80m using Belden 1694A. HD cable equalisation up to 140m with Belden 1694A or equivalent (approx. 100m with Belden 8281). SD cable equalisation >250m Belden 8281 or equivalent
Input return loss: -15dB for 50MHz to 1.5GHz and -10dB for 1.5GHz to 3GHz
Auto 50/59.94/60Hz and video format selection

VIDEO OUTPUTS
Two independent ports with two outputs of the main input and one output of the standby using RM53 and RM54 frame rear modules
270Mb/s or 1.5Gb/s or 3Gb/s serial compliant to EBU 3267-E, SMPTE 259M, SMPTE 292M and SMPTE 424M. Output follows the input format
The RM54 frame rear module provides relay bypass protection. An electromechanical relay switch needs power to hold the switch in one state and will revert to the other state (board bypass) on loss of power. It prevents signal loss by mechanically connecting the Smart Switch 3G’s main input to its main output 1 on complete frame power failure or board removal

DELAY THROUGH BOARD
10us max

SIGNAL CHECKS
Smart Switch 3G performs checks on the following parameters (listed in order of priority) which can trigger an automatic switch or activate the GPI output, with the user able to select a number of parameters in any combination:

* Input missing: Based on correctly positioned valid sync words in the data stream. If a valid input is not present then an alarm will be raised
* Input video standard incorrect: If a specific video standard is selected, then an input of a different standard will be treated as an error condition
* EDH missing (SD only): No EDH packets
* EDH full field error (SD only): Received EDH value does not match the data
* EDH active picture error (SD only): Received EDH value does not match the data
* Line CRC error (HD only): Received CRC value does not match the data
* Audio group 1 missing: If embedded audio group 1 is missing, an alarm is triggered
* Audio group 2 missing: If embedded audio group 2 is missing, an alarm is triggered
* Audio group 3 missing: If embedded audio group 3 is missing, an alarm is triggered
* Audio group 4 missing: If embedded audio group 4 is missing, an alarm is triggered
* Active video black: If all the luma samples within the active picture area are less than 13mV from nominal black value then an alarm will be triggered. The period of time for which the picture must remain black can be set from 2 to 60 seconds. The entire active picture must be continuously black for the full period – a single non-black sample restarts the delay period
* Active video frozen: An active picture checksum is calculated, and if it remains unchanged then the video is considered to be frozen and an alarm condition will be set. The period of time for which the picture must remain frozen can be set from 2 to 60 seconds. The entire active picture must be continuously frozen for the full period – a single non-frozen frame restarts the delay period
* Audio silence (channels 1, 2, 3 or 4): A separate audio level check is performed for each of the four channels in the selected group. If the audio signal level falls below -56dBFs for a period of time from 2 to 60 seconds, then an alarm is triggered. All four channels share the same silence time setting. The audio on the channels must be continuously silent for the full period – a single non-silent sample restarts the delay period
* Black AND channel 1 silent AND channel 2 silent: A logical combination of conditions, which only flag an error if all the conditions are met simultaneously
* Black AND channel 3 silent AND channel 4 silent: Only flags an error if all the conditions are met simultaneously
* Frozen AND channel 1 silent AND channel 2 silent: Only flags an error if all the conditions are met simultaneously
* Frozen AND channel 3 silent AND channel 4 silent: Only flags an error if all the conditions are met simultaneously

SWITCHING
The switch timing can be either immediate or timed and will apply to both outputs
Timed switching as defined in SMPTE RP168-2002 or immediate switching if primary input is faulty and standby is free of that fault. Smart Switch 3G will not switch away from the primary source if it detects that the standby source contains an error with a higher priority rating than the error detected on the primary source
A timed switch will occur in the correct time period according to the reference input (input 2 if valid)
The Smart Switch 3G can be set to switch back automatically or by user intervention
Automatically: the board will switch back if the original input returns to a valid state. A programmable delay can be added to ensure the previously faulty input remains good for the selected time period
User intervention: if the board auto switches away from an invalid input it will stay on the new selection until the routing is changed by the user, or the new input becomes invalid

LED INDICATION OF
Power supplies
Configuration progress
Input 1 valid
Input 2 valid
Main output source
Aux output source

GPI INPUT LEVELS
Active pull to ground, pulled up to +5V through 4700 ohm

GPI OUTPUT LEVELS
Electrically: Open collector transistors 48V, 270 ohm current limit resistors. Pulled up to +5V through 6800 ohm

GPI INPUTS
Five GPI inputs
Used to control input selection/routing, plus tally out
GPI control allows for direct connection to lamps and switches or to an automation system

GPI OUTPUTS
One GPI output
Will be asserted whenever a monitored error is encountered on either of the inputs
Can be configured to show an alarm condition for any individual or group of error conditions by ticking check boxes on Statesman

LOCAL CONTROL
Intuitive board edge interface with two select buttons, shaft encoder and ten character alphanumeric display

REMOTE CONTROL
RS422/485
19200 baud, 8 bits, 1 stop no parity
Control from frame active front panel and remote panel
Statesman allows control and status monitoring from any PC on a network. Statesman can be configured to ignore or create an alarm on any of the switching criteria by ticking the appropriate check boxes