| MECHANICAL
Standard Crystal Vision module 266mm x 100mm
Weight: 270g
Power consumption: 6.25 Watts
ANALOGUE INPUT
Digital input may be timed to an external analogue reference or free run with no reference
Mixed syncs input 300mV to 2 volt or 300mV Black and Burst into 75 ohm
Auto or manual 625/525 line selection
Reference loop-through available
Free-run frequency + or - 15 ppm
OUTPUTS
Two SDI outputs using the RM23 frame rear module
270Mbit to EBU 3267-E and SMPTE 259M
ADJUSTMENTS
0 to 1 line adjustment of horizontal picture position from syncs in 74ns steps
0 to 624 lines adjustment of vertical picture position in 1 line steps for PAL
0 to 524 lines adjustment of vertical picture position in 1 line steps for NTSC
BLANKING
To 601 specification vertically
One test pattern is available with signals on vertical lines 7 to 22 and 320 to 335 in PAL and 10 to 20 and 273 to 282 in NTSC
TEST PATTERNS
32 digital test patterns plus a full frame logo, divided into seven pattern banks:
100% Color Bars, EBU Color Bars, 95% Color Bars, Split Bars
Peak White, Black, Hard Grey, Red, Field 1 Only, Field 2 Only
Luma Only Ramp, Valid Ramp, Limit Ramp, 10 Bit Blue Ramp, Shallow Ramps, Steps, Modulated Ramp
Luma Only Multi-frequency Burst, Multi-frequency Burst, Luma Only Frequency Sweep, Frequency Sweep, Bow Tie
Mixed Selection of Patterns, SDI Test, Pulse and Bar, Edge of Frame Markers, Cross Hatch
PLUGE, SPLUGE, Co-site, 50Hz Rectangle, Safe Area
Crystal Vision Logo
A section of each test pattern can be made to rotate to create a moving pattern
GPI INPUTS
Pattern bank selection
LED INDICATION OF:
Power supply present, PAL/NTSC standard, board configured and ready for use, valid reference syncs input detected
LOCAL CONTROL
Rotary switch selection of pattern banks, static patterns and rotating patterns. Piano switch selection of line standards (when no reference syncs), EDH transmission, Y only or C only, horizontal and vertical delay adjustments
REMOTE CONTROL
RS422/485 and RS232
19200 baud 8 bits, 1 stop no parity
Remote control of pattern selection, 10 non-volatile user memory locations, Y only or C only, pattern rotation, horizontal and vertical delay adjustments |